Coax cable loss calculator

Matched-line loss for a feedline run, from the cable, the frequency and the length, with the connector losses on top, and how much of the power actually reaches the far end.

Each mated pair on the run.

0.1 dB is a typical UHF planning figure.

Total line loss2.15dB
Cable loss1.96dB
Connector loss0.20dB
Attenuation0.977dB / 100 ft
Power reaching the far end60.9%

Matched-line loss at room temperature. Installed loss runs higher with VSWR, heat, age and moisture, so treat this as a planning figure and add margin.

Runs in your browser; nothing you enter is sent anywhere. The same math the Sentinel RF product uses, tested against it. A planning figure, not an engineering sign-off.

The math

Attenuation follows the form cable datasheets publish:

A (dB per 100 ft) = k1 x sqrt(f) + k2 x f    f in MHz

k1 carries the conductor loss, which grows with the square root of frequency; k2 carries the dielectric loss, which grows with frequency itself. Each cable's constants come from the published datasheet of one common cable of that size and construction. Your cable's own datasheet is the authority.

Reading the result

3 dB of loss is half the power and 10 dB is a tenth. The same dB costs you in both directions: on transmit it comes off the ERP, and on receive, loss ahead of the first amplifier adds to the system noise figure dB for dB.

This is matched-line loss at room temperature. An installed run loses more with VSWR, heat, age and moisture, so carry margin.